This Variable Frequency AC Series Resonant Test System SXBP-5400kVA/72kV, 216kV, 432KV was consisted by following units:
♦ Variable Frequency Power Generator SXBP-250KW/220V, 380V 1 set
♦ HV Divider FRC-400KV/0.001-1000PF 1 set
♦ Exciting Transformer SXJB-250KVA/5KV /10KV/20KV 1 set
♦ HV Reactor SXDK-900kVA/72kV 6 pieces
♦ Accessories Box (connection wires)
Test object and requirements
1. 110KV busbar, testing frequency is 20-300Hz, testing voltage 185kV.
2. 110KV line insulator, switchgear, GIS, which test object without capacity. Testing frequency is 30-300Hz, the largest testing voltage 265kV.
3. 110kV,500mm2 cable 6000m, testing frequency is 30-300Hz, testing voltage 128kV.
4. 110KV/6300000KVA neutral point connect with earth main transformer directly, testing frequency is 30-300Hz, testing voltage 76KV.
5. 35KV,300mm2 cable 12000m, testing frequency is 30-300Hz, testing voltage 52KV.
6. 220KV 800mm2 cable 3000m , testing frequency is 30-300Hz, testing voltage 216KV.
Sansion power SXBP series test systems two operation modes: auto/ manual. Under auto mode, the operator only needs to set the voltage degree, withstand voltage time, then the system could find the resonance point and carry on the boosting automatically. The test report could be printed after test finished. Under manual mode, the voltage and current to be regulated by operator, and to find resonance point, print the test report manually.
Ex-work testing were completed successfully, all the test data was satisfied with the specifications.